Tortle Midliner FP

Adjustable, soft beanie designed with two support rolls which are made of polyurethane foam and soft forehead straps.

Its single layer construction from health grade fabrics provides high breathability, no dermal irritation together with a secure fit.  

Material:  95% cotton / 5% Lycra and lined with PU foam— this foam lined non-toxic tested material  is backed with research demonstrating safety even with micro-preemie skin as well as being Velcro receptive. This enables the use of multiple frequently needed attachments. 

The design is highly compatible with standard NICU devices including all brands and styles of nCPAP, nasal cannulas (no facial tape needed), feeding tubes, and more.  

Stable developmentally correct positioning (including neutral position during IVH protocol) with head boundaries from stabilization in the delivery room at birth to discharge from NICU  

Compatible with use of endotracheal tube while being ventilated as well as use with nCPAP, cannula (oxygen or feeding), as well as Tortle eye shades and quick release chin straps. 

Easy transition for intubated infant to nCPAP without loss of pressure/lung volume or respiratory decompensation 

Helps to prevent or reshape cranial asymmetry throughout time spent in NICU

This style is purpose-engineered for use with Fisher & Paykel respiratory equipment but can integrate seamlessly for use with all other respiratory devices. The Midliner FP maintains optimal consistent alignment of the head with fewer adjustments, reducing the manipulation and interruptions that can be injurious to the very preterm brain as well as stressful for these vulnerable infants.  

As a specialized infant medical device, this device ensures that critical care can be delivered without compromising positioning or accessibility. Its strap design allows easy for size adjustments and can be performed with minimal disruption to the patient. All of which has been shown to reduce the risk of IVH particularly during the first week of life, and also protects the laying down of neural pathways, a process which is usually complete by the time of discharge from the NICU.

Tortle Midliner FP

Device Weight (grams)
Tortle Midliner FP (ELBW) 17.25 g
Cannula Keys 0.71 g
Extra Velcro 0.30 g
Backstrap 0.86 g
Top Loader 1.94 g
Total Weight (grams) 0
Device Weight (grams)
Tortle Midliner FP (Micro Preemie) 26.60 g
Cannula Keys 0.71 g
Extra Velcro 0.30 g
Backstrap 0.86 g
Top Loader 1.94 g
Total Weight (grams) 0
Device Weight (grams)
Tortle Midliner FP (Preemie) 37.81 g
Cannula Keys 0.71 g
Extra Velcro 0.30 g
Backstrap 0.86 g
Top Loader 1.94 g
Total Weight (grams) 0

Instructions for Use

Download here

Frequently Asked Questions

How long can the Midliner remain in place?

"Time they are born until they go back to sleep as a late term infant" ** The Midliner may remain in place as long as it is clinically appropriate. Always inspect the infant's skin and positioning during routine care and reposition as clinically indicated. We recommend hand washing the Tortle Midliner weekly synchronizing with the routine respiratory device changes.

What size infant is the Midliner designed for?

The Midliner is intended for premature and low birth weight infants, from birth until the patient transitions to open bed status.

Can the baby be repositioned while using the Midliner? 

Yes. The Midliner supports recommended positioning strategies, including partial lateral tilt during IVH protocols. Follow your unit's positioning guidelines when repositioning the infant.

Is the Midliner reusable? 

Yes. The Midliner is reusable for a single patient when cleaned according to the provided laundering instructions. It should not be shared between patients.

What are the clinical benefits of using the Midliner?

When used as part of an established IVH prevention protocol, the Midliner helps: 

- Maintain neutral midline head positioning. 

- Support partial lateral positioning. 

- The standard Midliner allows for stable respiratory device attachment (ET Tube, some nCPAP, Oxygen cannula) 

- Reduce unnecessary handling. 

- Allow imaging and IV access without repositioning. 

- Support cranial symmetry by mimicking the in-utero environment. 

Does the Midliner replace standard IVH prevention protocols?

No. The Midliner is intended to complement, not replace your hospital's established IVH prevention and developmental care protocols. It should be used as part of a comprehensive clinical approach.

Interested in learning more?

Get in contact with your local Tortle distributor to learn more about  product and pricing.